Fire Alarm System

Conventional Fire Alarm System

•2, 4 and 8 zone panels

•30 detectors per zone

•2 x 3.2Ah, 12V batteries can be connected for 24 hours back-up

•EN54 complaint panels

•Model no. :EFCDP2Z – 2 zone panel, EFCDP4Z – 4 zone panel, EFCDP8Z – 8 zone panel

Conventional Detectors

•Common base platform for all conventional detectors

•Improved immunity to unwanted alarms on Photo thermal ‘dual’ detector

•Dual Blinking LED’s for 360° visibility

•Ideal for both fast-flaming and slow smouldering fires

•Can be addressed on addressable fire alarm panel with help of zone monitor module.

Conventional MCP’s and Sounders

•Approved to EN54: Pt 11

•Available as surface / flush and weatherproof (IP67)

•High output sounder beacon Sound output 101dB(A) at 24V dc

Addressable fire alarm system

•CF2000 : Standalone Panel

•2 loop Standalone panel

•Total 400 addressable Points

•CF1100/1200: Standalone Panels

•1~2 loop networkable panels

•Non Expandable panels

•Touch Screen Display

•CF3000: Expandable Panels

•2-4-8-12 loop networkable panels

•Touch Screen Display

•126 panels can be networked in one node

Repeater Panels

•CF3000PRG:

•LCD Loop repeater panel

•CF3000PRGNC:

•LCD Networkable repeater panel

•CTPR3000:

•Fully Touch Screen Networkable

   repeater panel

Fully touch screen networkable repeator panel

Requires no programming

• Large touch screen user interface

• Multi-language capability – user selectable

• Full network capability up to 126 panels

• Integral battery and power supply (EN54 Pt4)

• Programmable end user/engineer pass codes

• Programmable input (reset, evacuate, silence)

• Programmable volt free outputs

Detectors Family: Smoke, Multi and Heat detectors

•Soft addressed

•Inbuilt fault isolator

•Drift compensation

•Programmable “multi-mode” heat sensor

•Positive “lock” indication

•360° visibility LED using light-pipe technology

•Common mounting base

•Hard and/or soft addressing (Plug and Play for ease of commissioning)

Addressable Manual Call Point : CBG370S / CBG370WP

•Inbuilt S/C Isolator

•Software allocated addressing by panel

•Key operated testing

•Options

•Surface / flush

•Weatherproof IP66

•Accessories

•Replacement glass

•Hinged protective cover

•Loop Loading 200 max

Loop powered wall sounders and sound beacon: CAS381 / CASB383

•3 volume settings (controlled by panel)

•3 alarm tones (controlled by panel)

•Continuous 984Hz

•Two Tone 644 / 984Hz @ 1Hz cycle

•All tones may be pulsed  at 984 / 0Hz  pulse 1Hz

•Options

•Weatherproof IP65

•Loop Loading

•Low Volume excluding beacon = 60 max

•Subject to Loop Calculation; IMPORTANT

Conventional Pull Station : SG42BK2

•Wall mounting

•Single/dual action options

•ULMCIM-C requires for addressing

•Key reset

•High-gloss red enamel finish with raised white lettering

Conventional sounders and strobes : HSR/HNR

Full range of UL listed notification devices

Horns: HNR

Strobes: STR

Horn Strobes: HSR

Ceiling and wall devices

ULMCOM-S requires for addressing

3 audible and 8 candela settings

Interface Addresable modules: Control/ Monitor/ Zone Monitor module

•Addressable Input Module

•MCIM: For Flow Switch & beam detectors

•MCIM-C: Addressing Conventional MCP 

•Addressable Output Module

•MCOM: For AHU tripping & 3rd party integration

•MCOM-S: Addressing Conventional Sounder

•Addressable Zone Monitor Module

•MIU872: For Addressing Conventional Detectors

Beam Detectors: UL & EN54 Approved

MAB50R, MAB100R -Intelligent addresable loop powered reflective beam detector

Loop powered, Soft addressed & In-built fault Isolator

•Two range available – 50 meter & 100 meter

•Cover 15 meters width

•EN54 approved

•Combined transmitter and reflective type receiver unit in one unit

50RU/100RU – Conventional reflective beam detector

•Range: 5-50 Metres (50RU), 50-100 Metres (100RU)

•Selectable latching / non latching fire alarm

•UL certified

•LED indicators to aid the alignment process

•Selectable sensitivity/threshold levels

•Require monitor module to address on panel

Duct Detectors : MDP201

•Duct mounting probe unit is designed for use with

 Eaton’s range of addressable and conventional optical

 smoke sensors

• Presence of smoke in a ventilation duct is detecte

by sampling the airflow through the duct via two

  sampling tubes

•A detector and base are mounted within the sampling  chamber,

which is located on the external skin of the  duct, with sample and

exhaust probes passing into the duct in an area of low turbulence

Duct width ranges – 300mm to 1500mm

3D Graphical Visualization Software

•Graphical aid to manage alarm activations

•Programmable to suit any application

•3D idle/overview mode including mouse hover/click interaction

•Even 10,000 Buildings, 30,000 Floors/Graphics Screens 30,000, 100,000 Panel/Device Icons/Symbols & 50 Networks can be programmed

•Efficient management of critical systems

•Fire alarm

•Allows simple non-specialist administration

•PC based control

•Network history view/search, Max Events 99,999,999

•Audit trail

•Remote and multi-user access with defined credentials

•Password and pin code protected

Design a site like this with WordPress.com